Thermocouple Cables

Twisted Single Pair FEP Insulated

twist FEP1

twist FEP2

Application
These cables are used with thermocouples for temperature measurements.
Specification
Conductor: Solid or stranded. Material is according to thermocouple type.
Insulation: FEP polymer
Screen: Aluminum tape
Drain wire: Tinned copper
Outer sheath: FEP polymer
Construction: Round
Color code: According to IEC 60584-3

K Type

AWG(mm)

Insulation Material

Screen Material

Sheath
Material

Max. Temp. (°C)

Nominal O.D. (mm)

Weight (kg/km)

24 (0.51)

FEP Polymer
Aluminum tape
FEP Polymer

200

2.7

13.4

24 (7/0.2)

FEP Polymer
Aluminum tape
FEP Polymer

200

2.9

13.8

20 (0.81)

FEP Polymer
Aluminum tape
FEP Polymer

200

3.7

30.0

20 (7/0.32)

FEP Polymer
Aluminum tape
FEP Polymer

200

3.8

30.3